Overview
The device employs two activation methods that are more consistent with scientific fire suppression principles, enabling early detection and rapid extinguishing of fires and effectively reducing the damage caused by fires.
Working principle:
1. Temperature-activated startup: When a fire occurs and the ambient temperature rises to the preset value of the fire suppression system, the temperature-sensitive self-activation device on the fire suppression system is triggered, releasing ultra-fine dry powder extinguishing agent to put out the fire.
2. Electrically controlled, linked activation: The activation controller of the suspended fire suppression device can be connected to all fire alarm controllers. When a fire detector senses a fire signal and the controller confirms the fire, the fire suppression device automatically releases the extinguishing agent to put out the fire.
3. Manual Start: The on-duty personnel can activate the fire suppression system by pressing the manual button outside the protected area’s door.
This fire-extinguishing device consists of a fire-extinguishing agent tank, ultra-fine dry powder extinguishing agent, omnidirectional nozzles, a thermally or electrically initiated activation device, and mounting brackets, among other components.
Basic Parameters
Startup method |
Fixed-temperature heat-sensitive glass bulb |
68℃ |
|
Electric start |
DC24V/1A |
||
Installation height (m) |
≤6m when using total flooding fire suppression |
Spray Residual (%) |
≤5 |
Operating temperature range |
-10~+50℃ |
Storage pressure (20℃) |
1.2Mpa |
Device validity period |
10 years |
Hydrostatic test pressure |
2.1Mpa |
Model and Technical Parameters of Stored-Pressure Ultra-Fine Dry Powder Fire Extinguishing Systems
Model |
Fire suppression dosage (kg) |
Injection time (s) |
Protection space (m³) |
Product dimensions (mm) |
|---|---|---|---|---|
FZX-ACT2/1.2-HZ |
2 |
≤5S |
16 |
Φ210×180 |
FZX-ACT3/1.2-HZ |
3 |
25 |
Φ255×220 |
|
FZX-ACT4/1.2-HZ |
4 |
33 |
Φ255×260 |
|
FZX-ACT5/1.2-HZ |
5 |
41 |
Φ255×300 |
|
FZX-ACT6/1.2-HZ |
6 |
50 |
Φ300×285 |
|
FZX-ACT7/1.2-HZ |
7 |
≤10S |
58 |
Φ300×313 |
FZX-ACT8/1.2-HZ |
8 |
66 |
Φ300×341 |
|
FZX-ACT10/1.2-HZ |
10 |
83 |
Φ350×330 |
|
FZX-ACT12/1.2-HZ |
12 |
100 |
Φ314×424 |
Note Model designation for pressurized ultra-fine dry powder fire extinguishing systems: For example, FZX-ACT2/1.2-HZ. F – Dry powder fire extinguishing system; Z – Pressurized type; X – Suspended type; A – ABC dry powder; C – Ultra-fine dry powder; T – Standard application environment; 2 – Dry powder weight: 2 kg; 1.2 – Storage pressure; HZ – Represents the Hezhi brand logo.